High Voltage I,7lln some conditions, the key switch may be shorting (allowing some leakage) to the other terminals in the
ohmmeter on appropriate scaleConnect one meter lead to switch yellowred lead, the other meter lead to switch red leadDepress
switchMeter should show: Low reading when the switch is depressed High reading when the switch is releasedReplace the start
switch if your results vary Neutral Start Switch Test All engine wiring must be disconnected from the switch before proceeding
with this check 1Disassemble the remote control Calibrate ohmmeter on appropriate scaleConnect one meter lead to each switch
terminalMeter should show: High reading when the plunger is relaxed Low reading when the plunger is depressed 3Replace the
neutral start switch if your test results varyReassemble the remote control'" 4Test ALL functions of the remote control after
reassem- i blyAn undetected problem in the remote control could cause sudden and unexpected loss of throttle or shift control