1994 Johnson/Evinrude Electric outboards Service Manual, Page 45Get this manual

1994 Johnson/Evinrude Electric outboards Service Manual, Page 45

Resistor AssemblyHBF2 Only perform this check after completing Motor Tube Wiring HBF2 checks IT] 1Remove two thru-bolts and
If any lead shows no continuity, repair wire, or replace complete adapter housing, resistor coils, and wires5Connect second
meter lead to adapter housing: Meter must show no continuity If meter shows continuity, repair wire or replace adapter assembly6Repeat
Steps and with an ohmmeter calibrated on the low ohms scale to check the resistance values of the wires and resistorsThe
resistance values in Step should be: Speed LOW MED HIGH Terminal Color GrnIWht Green Red Approximate Resistance 0.6-0.80