Continuity TestPositive Circuit, 24 Volt Foot Control INotel To avoid damaging components or troubleshooting equipment, disconnect
repair or replace battery cable 8Connect second meter lead to RED 16-Galead at battery side of ONOFF switch: The meter must
show continuity9Move 1224 Volt switch to "24 V" position []] 10Move first meter lead to RED battery cable: The meter must
show continuity If meter shows no continuity in either test, replace 1224 Volt switch 11Connect second meter lead to RED
16-Galead at terminal"A" of speed control switchDepress ONOFF switch: The meter must show continuity If meter shows no continuity,
replace ONOFF switch or wiring12Connect second meter lead to GREENWHITE 18-Galead at terminal"3" of speed control switchTurn
speed control to speed and depress ONOFF switch: The meter must show continuity If meter shows no continuity, refer to Speed