1994 Johnson/Evinrude Electric outboards Service Manual, Page 51Get this manual

1994 Johnson/Evinrude Electric outboards Service Manual, Page 51

Continuity TestPositive Circuit, 24 Volt Hand Control INote To avoid damaging components or troubleshooting equipment, disconnect
cable at battery side of 1224 Volt switch: The meter must show continuity If meter shows no continuity in either test, repair
or replace battery cable rn 7Connect second meter lead to RED 16-Gawire at forward reverse switch: The meter must show continuity
6Move 1224 Volt switch to "12 V" position 8Move 1224 Volt switch to "24 V" position 9Move first meter lead to RED battery
cable: The meter must show continuity If meter shows no continuity in either test, replace 1224 Volt switch 10Move forwardreverse