1994 Johnson/Evinrude Electric outboards Service Manual, Page 104Get this manual

1994 Johnson/Evinrude Electric outboards Service Manual, Page 104

Test circuit must contain ft(3 m) of 14 gauge wire Test circuit must contain ft(1,5 m) of 14 gauge wire 12-Volt Motors 24-Volt
different, and the motor should operate at different speed at each switch position5If the electric motor does not operate
at each switch position or if the ammeter reading or motor speed is not different at each switch position, note the exact
symptoms Use these symptoms and the Trouble Check Charts on Pages 2-6 and 2-7 to determine what failed parts would lead to
those symptoms Armature Shaft End Play Adjustment Except HBF2 1If the adjustment screw has been removed, apply OMC Screw
Lock to threads of the screwStart the screw into the head end assembly2Connect motor to the circuit and tighten the adjustment