Static TestingAll Models Continuity Test[1Check motor with an ohmmeterCalibrate ohmmeter on high ohms scaleGround one ohmmeter
motor in the test circuit shown [] 2Connect torque wrench to the motor Turn motor on and note the voltage, torque, and amperage
readings INote Do not run motor stalled and out of water any longer than is absolutely necessary to take reading and never
for longer than 10 seconds No Load Test Model RPM 12 VoltExcept HBF2 12 Volt HBF2 12 Volt High-Thrust 24 Volt 24 Volt High-Thrust
20002175 15001800 16001800 24752600 16151785 AMPS (Max 3 VOLTAGE (Min 10.5 10.5 10.5 22 22 Stall Torque Test AMPS (Max 105
120 90 90 100 TORQUE (Min 31 inIbs39 inIbs38 inIbs31 inIbs65 in Ibs t See pages 1-21 or 4-10 for motor identification If