6Test the "no oil" warning circuit: Connect shop tank with 50: fueloil mix to the fuel inlet fitting Remove the protective
Install the oil hose on the oil inlet fittingUse only the ratchet clamp supplied with the kit to secure the lineTighten with
pliers To complete priming, squeeze oil primer bulb until oil is visible at the sight tube located in the oil hose near the
pump During the break-in period, the engine's fuel tank must have 50fueloil mixture in addition to operation rr:i=J Prime
the oil system before priming fuel systemIf fuel system is primed first, the oil system must be primed with the engine idlingPrime
until oil is visible at the sight tubepumpWarning horn will sound until oil reaches the 8Store the protective cap removed
from the oil inlet fitting on the yellow cap holder attached to the VRO fuel hose9The oil level must be marked on the side
of the reservoir before putting the engine into service After the break-in period, the operator must verify that oil has