1994 Johnson/Evinrude Outboards 40 thru 55 Service Manual, Page 277Get this manual

1994 Johnson/Evinrude Outboards 40 thru 55 Service Manual, Page 277

Starter Circuit Check ChartRemote Control Models INotel Battery must be fully chargedStep Procedure Remove black lead from
is open between CD and INotel Steps thru Turn key OFF before connecting and disconnecting meterTurn key to START position
after connecting .bIf no reading, go to Step I!I Check voltage iii and between ground Connect meter at START position aIf
meter reads battery voltage, solenoid is faultybIf no readinggo to Step II Check voltage between ground Connect meter atTurn
key to START position aIf meter reads battery voltage, lead is open between and or neutral start switch is open or improperly
adjustedbIf no reading, go to Step Check voltage between ground and Connect meter at OFF position aIf meter reads battery