Stator Resistance Check12 Amp Models c=J Disconnect battery cables before proceeding with this N checkf311Disconnect stator
if reading is not correct3To check for grounded condition, disconnect both ohmmeter leadsCalibrate ohmmeter on appropriate
scaleConnect one ohmmeter lead to clean engine ground and the other ohmmeter lead alternately to both stator leads Ohmmeter
should show high reading If ohmmeter shows low reading, stator is grounded and should be repaired or replacedAfter replacing