6Test theno oil" warning circuit: Connect shoptankwith 50:1 fueloil mixtothefuel inlet fitting Remove the protective cap
oil hose on the oil inlet fittingUse only the clamp supplied with the kit to secure the line To complete priming, squeeze
the oil primer bulb until oil is visible at the sight tube located in the oil hose near pumpthe During the break-in period,
the engine's fuel tank must have 50: fueloil mixture in addition to operation Prime the oil system before priming fuel systemIf
fuel system is primed first, the oil system must be primed with the engine idlingPrime until oil is visible at the sight
tubeWarning pumphorn will sound until oil reaches the 8Store the protective cap removed from the oil inlet fitting on the
yellow cap holder attached to the VRO fuel hose9The oil level must be marked on the side of the reservoir before putting
the engine into service After the break-in period, the operator must verify that oil has been used before switching to clear