1995 Johnson Evinrude "EO" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 503151, Page 106Get this manual

1995 Johnson Evinrude "EO" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 503151, Page 106

Ignition Coil Tests Many ignition testers are available from various manufacturersIn addition, some automotive testers having
Analyzer Polarity Ohmmeter Tests Resistance tests may be performed while the ignition coil is still mounted on the powerhead1Twist
and remove the spark plug and primary leads from the ignition coilf1l 2Calibrate ohmmeter on appropriate scaleConnect meter
black lead to clean engine groundIf the coil is not mounted on the engi'ne, connect meter black lead to ground tab on the
coilConnect meter red lead to coil primary terminal Meter must show 0.1 0.05 ohm t=J red lead to coil primary terminalConnect
meter black lead to coil spark plug terminal Meter must show 275 50 ohms f21 3Calibrate ohmmeter on appropriate scaleConnect
meter 4Test spark plug leads for continuityCalibrate ohmmeter on low ohms scaleAttach one ohmmeter lead to each spring terminalWhile