3 Ohmmeter TestKey Switch INotel All ohmmeter tests must be performed with the engine NOT running1Disconnect the port side
reading I Note V6Repeat Step using remaining blackyellow leadIf the ohmmeter test on both leads are good, the power pack
blocking diode is shortedReplace the power pack5If Step key ON reading is low one, disconnect harness blackyellow leads from
key switch "M" terminal: If meter shows high reading, test the key switchRefer to Electrical Section If meter shows low reading,
go to Step 66Separate the emergency stop switch lead from the harness blackyellow lead at the key switch: If meter shows
high reading, test the emergency stop switch If meter shows low reading, test the wiring harness7If the engine fails to shut