1995 Johnson Evinrude "EO" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 503151, Page 125Get this manual

1995 Johnson Evinrude "EO" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 503151, Page 125

STEPCHARGE COIL TEST, V6 MODELS Ground Test 1Disconnect the starboard side connector between stator and power pack2Attach
lead and meter red lead attached to brownwhite stator lead: If meter shows 150 volts or higher, go to next step indicated
in Troubleshooting Sequence Chart, Page 3-24 If meter shows less than 150 volts, check condition of wiring and connectors
If wiring and connector condition is good, go to Ohmmeter TestOhmmeter Test INote All ohmmeter tests must be performed with
engine NOT running 1Calibrate ohmmeter on appropriate scale2Connect meter between stator brown and brownyellow leads: Meter
must show 550 55 ohms 3To test for grounded condition, connect ohmmeter black lead to clean engine groundAlternately connect
ohmmeter red lead between brown, brownyellow leads: Any needle movement indicates charge coil or leads are grounded locate
and repair ground, or replace stator assembly4Repeat Steps and using brownblack and brownwhite stator leads5Complete all