1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 86Get this manual

1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 86

Installation Recommendations Carefully, follow the installation instructions packaged with the VRO oil reservoirIncorrect
to maximum of 25 ft(7,6 m)If the installation is extended, the oil hose between the primer bulb and engine must be one continuous
section with no fittings or connectionsDo not add on to the existing hoseThe wiring harness can be extended by soldering
on additional 16-gauge wire to each leadProtect the connections with shrink tube and electrical tapeObserve proper wire color
for identification 4When making connections in the oil supply system, use only the clamp supplied with the system Do not
use tie strapsThey do not provide adequate clamping action Do not use metal worm clamp on vinyl hoseIt can damage the hose
and cause leakage5Test the "low oil" warning circuit before filling the oil reservoir: Make all electrical connections and
connect the engine's battery Turn the key switch ON With the reservoir empty, the warning horn should sound for 12 second