1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 151Get this manual

1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 151

Ohmmeter TestKey Switch All ohmmeter tests must be performed with the engine not running 1Separate blackyellow lead 1-pin
reading Key ON, meter must show high reading4If Step key ON reading is low one, disconnect harness blackyellow leads from
key switch "M" terminal If meter now shows high reading, test key switchRefer to Electrical Section If meter shows low reading,
go to Step 55Separate emergency stop switch lead from harness blackyellow lead at key switch If meter now shows high reading,