13 DR4072 DR4073 STEPSENSOR COIL TEST Ground Test 1Disconnect the two 5-pin Amphenol connectors between the timer base and
"A", "8", "C", and "0" and port connector, terminals "A", "8 "e", and "0" 3Crank engine and observe meter at each connection
If meter shows 0.2 volt or higher, go to Step If meter shows less than 0.2 volt, check condition of wiring and connectors
If wiring and connector condition is good, go to Ohmmeter Test 4Connect the "E" terminals in the separated port timer base
connector using jumper wireConnect the "E" terminals in the separated starboard timer base connector using jumper wire5Attach
the voltmeter black lead to clean engine groundAttach meter red lead alternately to starboard connector, terminals "A", "8",
"C", and0" and port connector, terminals "A", "8", "C", and "0"6Crank engine and observe meter at each connection If meter