Sensor Coil Ohmmeter Test INote All running ohmmeter tests must be performed with engine not 18efore proceeding, you must
M-700 meter: 970 100 ohms Fluke 29 Series II meter: 975 100 ohms The Fluke 29 Series II meter must be set to the low ohms
(40 0,) scale for this testRead the operating instructions that came with the meterOhmmeter readings will vary with individual
meter impedanceYour readings might be slightly higher or lower, but should all be approximately equal 5Attach ohmmeter red
lead to port timer base connector, terminal "E"Attach meter black lead to starboard timer base connector, terminal "E" Meter
should read 160 20 ohms To test for grounded condition, connect ohmmeter alternately between each port and starboard terminal
location and clean engine ground Meter must show high reading If meter shows low reading, locate and repair ground or replace