1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 284Get this manual

1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 284

19Pull up on the detent lever until it snaps into the NEUTRAL positionPush the pivot pin out of the housing, then reach
the bearing retaining ring on top side of the pinion bearing, using long-handle needle-nose pliers such as Snap-On No911
CP or equivalentIf the pinion bearing must be replaced, use OMC Bearing Remover and Installer, PIN 391257, and assemble it
as follows: PIN 326586 Flange Nut PIN 391260 Plate PIN 326579 Remover PIN 326582 Rod INotel Make sure all 18 needle bearings
are inside the bearing case before pulling the bearingThe needles provide surface for the remover to pull against Use 13s
inwrench to hold the remover in placeUse 3f4 inwrench to turn the flange nut clockwiseDraw the bearing up and out of the
gearcase 24Inspect the water screen for blockageRemove the water intake screens by removing screwsRemove both halves of the