1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 345Get this manual

1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 345

Starter Circuit Check Chart INote Battery must be fully charged Procedure Remove black lead from ground at CDConnect voltmeter
and Steps thru key OFF before connecting and disconnecting meterTurn key to START position after connectingConnect meter
at START position bIf no reading, go to Step Check voltage between ground and Turn key to aIf meter reads battery voltagesolenoid
is faultybIf no reading, go to Step I) II Check voltage between ground Connect meter atTurn key to START position aIf meter
reads battery voltage, lead is open between and or neutral start switch is open or improperly adjusted bIf no readinggo to
Step P.I Check voltage iii and between ground Connect meter atTurn key to OFF position aIf meter reads battery volt age,