1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 350Get this manual

1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 350

Solenoid Check INotel All engine wiring must be disconnected from the solenoid before proceeding with this test 1Calibrate
Starter I Note Securely fasten starter in vise or other suitable fixture before proceeding with this check1Locate battery
rated at 500 CCA (60 amphrs or higher that is in good condition and fully charged 2Connect 0-100 amp ammeter in series with
heavy jumper between the battery "+" terminal and the starter "+" terminal 3Attach or hold vibration tachometer, such as
Frahm Reed tachometer, to the starter rn 4Complete the and the with heavy jumper between the circuit battery "-" terminal
starter frame5Monitor the starter RPM and current draw and refer to the chart below for the correct specificationsNo Load
Current Draw Specifications Amps (Maximum) 36 30 Model V4 V6, Voltage 1212.4 1212.4 5350 (Minimum) PCE0059 When performing