1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 409Get this manual

1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 409

Tilt Limit Switch If the engine contacts the boat's motor well when fully tilted, adjust the tilt limit cam to lower full-tilt
position or modifying the boat if the possibility for interference and damage exists Routine Inspections 1Check reservoir
fluid level at least once per season or every 50 operating hoursSystem capacity is approximately 21 floz(622 ml) Tilt the
engine up and engage the tilt support Slowing open fill capallowing air to escapeAdd OMC Power TrimlTiltPower Steering Fluid
or GM Dexron II, as needed, to bring fluid level up to the bottom of the fill cap hole Replace fill cap and disengage tilt
supportCycle unit down, then up; pausing between cycles and adding fluid as neededA minimum of five complete cycles is required
to purge air drawn in because of low fluid level2Look for indications of external fluid leakageCorrect the cause if leaks
are noted& 3Torque the manual release valve to 45-55 inIbs(5-6 Nm) 4Inspect the stern brackets for binding with the swivel