1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 424Get this manual

1995 Johnson/Evinrude Outboards 125-300 90 degree LV Service Manual, Page 424

Power Supply TroubleshootingV4 Before beginning this procedure: Charge battery and connect battery cablesTurn key switch
sockets [!] 4Connect voltmeter red lead to V1 and black lead to V2 in the UP (blue) relay socket If no voltage at V1, check
red wire between starter solenoid terminal and relay socketIf red wire is OK, check black wire between relay socket and engine
ground If voltage at V1, go to Step 5 [!] 5Connect voltmeter black lead to clean engine ground, and voltmeter red lead to
V3 (bluewhite)[!] 6Push control box UP trim button If no voltage at V3, check control box trim switch and wiring If voltage
at V3, go to Step 7 GJ 7Push lower motor cover UP trim button If no voltage at V3, check for voltage at bluewhite bullet