1995 Johnson/Evinrude Outboards 25, 35 3-Cylinder Service Manual, Page 258Get this manual

1995 Johnson/Evinrude Outboards 25, 35 3-Cylinder Service Manual, Page 258

Routine Inspections 1Check reservoir fluid level at least once per season or every 100 operating hoursSystem capacity is
cycling the unit, hold the trim switch ON an additional to 10 seconds after the unit reaches the end of its travel before
activating the switch in the opposite direction & 2Check the manual release valve with torque wrenchThe valve must be tightened
to 45-55 inIbs(5-6 Nm)3Check for external signs of fluid leakageCorrect causes as necessary4Inspect the stern brackets for
binding with the swivel bracket in the thrust rod areaRetighten the tilt tube nuts as follows: Tighten the tilt tube nuts