1995 Johnson/Evinrude Outboards 50 thru 70 3-cylinder Service Manual, Page 265Get this manual

1995 Johnson/Evinrude Outboards 50 thru 70 3-cylinder Service Manual, Page 265

Tilt Limit Switch Icllcl lf the engine contacts the boat's motor well when fully tilted, adjust the tilt limit cam to lower
position or modifying the boat if the possibility for interference and damage exists Routine Inspections f71 1Check reservoir
fluid level at least once per season or every 50 operating hoursSystem capacity is approximately 21 floz(622 mil Tilt the
engine up and engage the tilt support Remove the fill cap and add OMC Power TrimiTiltPower Steering Fluid or GM Dexron II,
as needed, to bring fluid level up to the bottom of the fill cap hole Replace fill cap and disengage tilt supportCycle unit
down, then up; pausing between cycles and adding fluid as neededA minimum of five complete cycles is required to purge air
drawn in because of low fluid level2Look for indications of external fluid leakageCorrect the cause if leaks are noted 3Torque
the manual release valve to 45-55 inIbs(5-6 4Inspect the stern brackets for binding with the swivel bracket in the trim limiter