1996 Johnson Evinrude "ED" 40 thru 55 2-Cylinder Service Manual, P/N 507124, Page 267Get this manual

1996 Johnson Evinrude "ED" 40 thru 55 2-Cylinder Service Manual, P/N 507124, Page 267

Starter Circuit CheckTEL, TTL 1 Avoid accidental starting while testing; disconnect the starter cable at point CD before
voltmeter between and ground IIIf meter shows 12V, go to Step IIIf meter reads OV, go to Step II II Check voltage tween and
ground If meter shows 12V, replace start button andor wire If meter shows OV, go to Step II Check voltage tween and ground
If meter shows 12V, go to Key Switch Check, this sectionCh eck wire to terminal strip If meter shows OV, go to Step Check
voltage tween and ground Connect voltmeter between and ground If meter shows 12V, replace fu se, holder, or wire to key switch.If
meter shows OV, replace wire from solenoid terminal to fuse 0 II Check voltage tween and ground Disconnect black ground wires
from Connect voltmeter between solenoid terminal and groundTurn key switch ON Push start switch If meter shows 12V, repairreplace
black wire between and ground If meter shows OV, disconnect all leads from solenoid, and test so lenoidGo to Solenoid Check,