1996 Johnson Evinrude "ED" 40 thru 55 2-Cylinder Service Manual, P/N 507124, Page 274Get this manual

1996 Johnson Evinrude "ED" 40 thru 55 2-Cylinder Service Manual, P/N 507124, Page 274

High Voltage In some conditions, the key switch may be shorting (allowing some leakage) to the other terminals in the key
the red lead of the tester to the "8" terminal and apply leakage test2Repeat test by moving the red lead to each of the terminals
and applying the leakage testThe meter will indicate if leakage is present3When applying test to other "M" terminal, turn
key to the "ON" position DRC5899 Start Switch Ohmmeter TestsTEL, TTL Disconnect the two switch leads from the starter solenoidCalibrate
ohmmeter on appropriate scaleConnect one meter lead to switch yellowred lead, the other meter lead to switch red leadDepress