Cranking Discharge Method 1Check battery voltage If voltage is greater than 12.5 volts, go to Step If voltage is less than
of the starter solenoid4Reconnect the engine's battery cablesReconnect the ignition charge coilconnector(s) INote The rectifierregulator
requires battery voltage on the purple lead to operateBefore proceeding, verify battery voltage at terminal strip purple
leads when key is ON 5Start the engine and run it at approximately 4500 RPMThe engine's ammeter should indicate nearly full
output12 ampsAs the engine continues to run at 4500 RPM, the voltage should stabilize at approximately 14.5 volts and the