1996 Johnson Evinrude "ED" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 507127, Page 44Get this manual

1996 Johnson Evinrude "ED" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 507127, Page 44

Shift Cable 1Extend shift cable and lubricate with OMC Triple-Guard grease2Verify that the remote control fast idle lever
on the shift cable to allow the adjustment in Step 7, or if the gearcase detent does not correspond with remote control NEUTRAL
in Step 10, refer to Section for shift rod height adjustment11 Attach shift cable to shift lever pin using cotter clip and
washer supplied with engine INote When i nsta II ng OMC accessory controls, except for prewired surface mount, the shift
cable must be adjusted and installed when the control and engine are in NEUTRAL12Install the cable retainer and torque screw
to 60-84 inIbs(7-9 Nm)Install the cable grommet and anchor block cover 11 13Inspect installation to ensure that the control
cables are attached to the proper engine levers by lifting the fast idle lever to the START positionIf correctly attached,
the throttle cable and engine throttle lever will move INotel When installing remote control that is not manufactured by