1996 Johnson Evinrude "ED" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 507127, Page 110Get this manual

1996 Johnson Evinrude "ED" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 507127, Page 110

Tests Using Ignition Analyzer When conducting these tests to the coildo not exceed its maximum specified amperagePower Test
Leakage Test The ignition coil and spark plug lead should be tested for leakage or insulation failures using the ignition
analyzerLeakage is caused by moisture, cracks, or holes in the coil housing or spark plug leads Isl With the analyzer's black
and red leads still connected from the Power Test, remove the analyzer's high tension lead from the coilTurn on the analyzer
and probe the entire surfaces of the coil, spark plug lead, and spark plug coverFlashover will be apparent wherever insulation