STEPTIMING SENSOR TEST INote Sources of intense light can disrupt the optical ignition sensor, causing misfireAvoid running
source W 4Move analyzer selector switch to position: V4- "B" V6- "A" 5Press "RESET" button on analyzer 6Crank engine continuously
for minimum of three revolutions7Observe meter: If "GOOD" indicator light flashes during cranking, proceed to next step indicated
in Troubleshoot ing Sequence Chart, Page 3-24 If "BAD" indicator light flashes during cranking or the "GOOD" and "BAD" indicator