1996 Johnson Evinrude "ED" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 507127, Page 243Get this manual

1996 Johnson Evinrude "ED" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 507127, Page 243

Starter Circuit Check Chart INote Battery must be fully chargedStep Procedure Remove black lead from ground at G) Connect
INote Steps fJ thru Turn key OFF before connecting and disconnecting meterTurn key to START position after connectingbetween
ground Connect meter at Turn key to START position bIf no reading, go to Step II Check voltage aIf meter reads battery voltage,
solenoid is faultybIf no readinggo to Step Check voltage between ground and Connect meter at Turn key to START position aIf
meter reads battery voltage, lead is open between and or neutral start switch is open or improperly adjustedbIf no reading,
go to Step II Check voltage between ground Connect meter at OFF position aIf meter reads battery voltage, check key switchbIf