Starter System Voltage Drop Test By making systematic check of the starter system, any component or electrical connection
only while the engine is cranking, or damage to the voltmeter can occur2Connect voltmeter negative lead to the starter side
of the starter solenoid terminalWhile cranking engine, connect voltmeter positive lead to starter solenoid opposite terminalVoltage
reading should not exceed 0.2 voltRemove voltmeter positive lead from starter solenoid and stop cranking engine3Connect voltmeter
positive lead to starter solenoid, starter lead terminalConnect voltmeter negative lead to starter motor terminalTurn key
switch to STARTVoltage reading should not exceed 0.2 volt4Connect voltmeter positive lead to battery negative lead common