Cranking Discharge Method 1Check battery voltage If voltage is greater than 12.5 volts, go to Step If voltage is less than
battery cables and the spark plug leads INote The rectifierregulator requires battery voltage from the purple lead to operateBefore
proceeding, separate the rectifier regulator purple lead bullet connectorVerify battery voltage at the engine harness connector
when key is ON Reconnect the purple lead bullet connector 6Start the engine and run it at approximately 4500 RPMThe ammeter
should indicate nearly full output20 or 35 ampsWhile continuing to run at 4500 RPM, the voltage should stabilize at about