FUEL SYSTEM (Proarammed Fuel Iniection) 4Wastegate Actuator Inspection Pull the safety lanyard lock clip off of the engine
memory in the ECM (page 8-17)Start the engine according to the flushing procedure (page 5-3) and increase the engine speed
above 3,000 rpmCheck the TCP sensor with the HDSIs DTC 45- indicated? - Replace the ECM with new one, and inspect again -
Replace the original TCP sensor with a DTC 46-1 (MST SWITCH) Before starting the troubleshooting, check the MST switch (Black)
connector for loose contacts or corroded terminals, and recheck the DTC1MST Switch Line Inspection Pull the safety lanyard
lock clip off of the engine stop switchDisconnect the MST switch 2P (Black) connectorInsert the safety lanyard lock clip
in engine stop switchMeasure the voltage between the wire harness side connector terminalsConnection: Whitelblack (+)Green