ELECTRICAL RPM Limiter Circuits RPM Limiter Function1997 SL780, SLT780, SLTX, SL1050) An RPM limiting system (see models
limiting functionSee diagrams belowLow Fuel No low fuel limiters are present on these models Important Note: When the engine
overheat circuit has caused the system to limit, it will continue to limit until both of the following conditions are met:
1The problem that caused the initial limiting must be corrected (cool engine); AND 2The operator must momentarily release
the throttle and allow the RPM to fall below 4200 or 4500.I- COl Unit tan Multi-Function Display Terminal Board Electrical
Box 1997 SL780, SLT780 When limiter circuit is activated engine RPM will be limited to 4200 Thermal Switch (on engine) Electrical
Box COl Unit Multi-Function Display Terminal Board 1997 SLTX, SL1050 When limiter circuit is activated engine RPM will be