MAINTENANCElTUNE UP Electrical Replenishing Battery Fluid The fluid level should be kept between the upper and lower level
could ignite them which could cause personal injuryWhen reinstalling battery connect black (negative) cable lastWARNING Keep
the battery away from sparks and open flames during charging because the battery gives off gases which are explosiveIf you
smell fuel do not attempt to charge the batteryWhen using battery charger connect the battery to the charger before turning
on the charger, This prevents the possibility of sparks at the terminals which could ignite the battery gasesDo not connect
charger cables to the battery unless the charger is unplugged12Remove caps from cellsAdd distilled water if necessary to
bring electrolyte up to proper levelConnect battery to chargerSet charging rate at1 ,9 amps (maximum) and charge battery
for ten hours CAUTION: During charging, if the electrolyte temperature rises above 115F (45C) or jf battery feels hot when
touched, reduce the charging rate to lower the temperature and increase the charging time34After battery is charged, check