FINAL DRIVEJET PUMPBILGE SYSTEM Pump Intake 1999 X-45 Use Marine Grade Silicone Sealant (PN 8560054)Allow sealant to cure
Silicone Sealant between hullscoop edgesClean excess silicone after installationNOTE: If inlet scoop is damaged or bent during
removalreplace with new scoop Ride Plate IMPORTANT! Apply continuous bead of Marine Grade Silicone Sealant to ride plate
sealing areaNOTE: Cavitation may result if silicone is not continuously applied; e.gpin holes, separation, or damageAllow