1999 Polaris PWC Genesis, Ficht, X-45 Service Manual, Page 224Get this manual

1999 Polaris PWC Genesis, Ficht, X-45 Service Manual, Page 224

ELECTRICAL Specifications Warning Systems Operating Characteristics Following is quick reference chart showing how each model
when measuring small resistance valuesMeter readings were obtained using either FlukeTM 73 or TektronixTM DMM 155 digital
mullitesterUse of other meters may produce different results 1999 GenesisX-45 Component Alternator Coil" Alternator Coil
Trigger Coil Exciter Coil Exciter Coil Wire Colors (Connect Ohmmeter Leads To): RedPurple to Yellow RedPurple or Yellow to
Ground Refer to test procedure in this section Black to Purple Black to Ground 5.5 ohms ohms Reading .75 ohms (Continuity)
(No continuity) Ignition Coils, Each Primary" Secondary Connections YellowBrown to BlkJWhite; BlkGreen to BlkJWhite; or BlkBlue
to BlkJWhite Inside spark plug cap to black coil wire, or inside spark plug cap to ground Readings .35 ohms (Continuity)
16.5'" (424 mm) length wire: 3700 ohms 22" (563 mm) length wire4540 ohms 28" (714 mm) length wire: 5190 ohms NOTE: Most meters
will not be able to measure resistance this lowTouch the meter leads together, view your meter, and record this readingMeasure