1999 Polaris PWC Genesis, Ficht, X-45 Service Manual, Page 228Get this manual

1999 Polaris PWC Genesis, Ficht, X-45 Service Manual, Page 228

ELECTRICAL Charging System Genesis X45 Electrical Testing Digital MultitesterThe Fluke 73 The easiest and most accurate method
when the diodes are out of circuitAmps ACnot usedAmps DCused to check battery charge rate, system draws, etcNOTE: When using
the Amp settings, the red test lead must be moved to the lOA (unlused) socket on the front 01 the instrument Charging System
Testing (Unregulated Voltage) 123Remove electrical box cover for component accessTurn multitester dial to Volts AC) positionDisconnect
alternator-to-main harness connector at electrical boxConnect one of the tester leads to the yellow alternator wire and the
other lead to the redpurple alternator wireStart engineWhile observing VOltage reading, increase engine speed to about 3000
RPM Readings should be above 20 VACIf output is low, test stator coils with an ohmmeterRefer to page 7.3 for connections