ELECTRICAL Battery Testing Specific Gravity Test A tool such as the battery hydrometer can be used to measure electrolyte
25 Charged Charged CONVENTIONAL LEAD-ACID 1.265 1.210 1.160 1.120 less than 1.100 YUMICRON TYPE 1.275 1.225 1.175 Detail
A less than 1.115 NOTE: Subtract .01 from the specific gravity reading at 40 F Battery Hydrometer PN 2870836 Load Test battery
may indicate full charge condition in the OCV test and the specific gravity test, but still not have the storage capacity
necessary to properly function in the electrical systemFor this reason battery capacity or load test should be conducted
whenever poor battery performance is encounteredNOTE: This test cannot be pertormed with an engine or starting system that
is not working properly12Attach multitester to the batteryThe reading should be 12.4 volts or greaterEngage electric starter
and view registered battery VOltage while cranking engineContinue the test for 15 secondsDuring this cranking period, the