ELECTRICAL Battery Maintenance Refilling Low Battery The normal chargedischarge cycle of battery causes the cells to give
if necessaryCharge at rate no greater than 110 of the battery's amplhr capacity until the electrolyte's specific gravity
reaches 1.270 or greaterStore battery either in machine with cables disconnected, or store in cool dry place NOTE: Stored
batteries lose their charge at the rate of per dayThey should be recharged to full charge every 60 to 90 days during non-use
periodIf stored during the winter months, the electrolyte wi ll freeze at higher temperature as the battery dischargesThe
chart below indicates freezing points by specific gravityELECTROLYTE FREEZING POINTS Specific Gravity of Electrolyte Freezing
Point -75F -35F -l +5 +18F +2rF 1.265 1.225 1.200 1.100 1.050 Charging Procedure Charge the battery with charger no larger
than 110 of the battery's amplhr rating for as many hours as needed to raise the specific gravity to 1.270 or greater WARNING