1999 Polaris PWC Genesis, Ficht, X-45 Service Manual, Page 239Get this manual

1999 Polaris PWC Genesis, Ficht, X-45 Service Manual, Page 239

ELECTRICAL Temperature WarningGenesis X-45 Cool ant Temperature Warning ircuit Operation The MFOMFI light is controlled by
the sensor is located on the exhaust manifoldGround the sensor wire from MFDMFI with engine running to see if temp light
activatesRefer to MFOMFI functiontesting in this section Temperature Sensor Test The temperaturewaming switch is normally
openUsing digital VOM set in the Ohms position, and with the wires disconnected, contact one test probe to the switch terminal
and the other test probe to engine groundThe meter should show an open circuitHeat the switch in water bath to the "on" temperature
listed on page 7.3Measure resistance of the switchReading should be less than .4 ohms CAUTION:- When testing the switch,