1999 Polaris PWC Genesis, Ficht, X-45 Service Manual, Page 253Get this manual

1999 Polaris PWC Genesis, Ficht, X-45 Service Manual, Page 253

ELECTRICAL Trigger Coil TestingGenesis X-4S Trigger Coil (Hall Effect Sensor) Testing The ''trigger coils" are Half Effect
((XI) until the magnet in the magnet holder passes by the sensorAt this point the reading should switch to low resistance
(under 25 ohms)It should go back 10 infinite as flywheel rotation continuesRepeat the test for the other trigger coils Ohmmete
Twin Cylinder Shown Check wiring diagrams for specific model NOTE: Actual resistance readings may vary with different metersA
specific resistance reading is not criticalThe reading must, however, switch sharply from high to low resistance, and then
back again as the flywheel is rotated Alternate Method Of Testing Hall Effect Sensors Static Timing Ught tool (PN 2871745)
can used to test Hall Effecl sensorsSimply connect the white test wire to the Red (Mag), Blue (Cen), or Green (PTO) wire
from the slatorIf the sensor is functioning properly, the light will turn on and off as indicated in Static Timing Procedure