DIAGNOSTIC SOFTWARE Diagnostic Session Retest Option Some Hard Codes have Retes! andor associated Static Test optionIf these
to diagnose and verify some repairsFor example; Service Code #43 wi ll be set if an open connection occurs in the Coolant
Temperature sensor circuit The Code screen for Service Code #43 has the Retest featureIf you press "R", the Retest screen
will be displayedIf you wiggle the Coolant Temperature sensor connector and it momentarily improves contact, the computer
will when the connection is goodThe computer will then display message that the code appears to be repai red The problem
using this ser vice code is still detec edConduc visual inspection, check and clean connections, and test components The
computer will beep and then the screen will change when the problem is repaired PRESS ANY KEY TO STOP If the connection breaks,
the computer will beep again and display the Retest screenWhen you exit the Retest feature, you wi ll automatically return
to the Code screenThe Class fiel wi ll reflect the status of the Service Code; either Hard or Repaired When you are finished