ENGINECOOLING Exhaust Valve InspectionCleaningAdjustmentPro 785 Adjustment The correct position of the exhaust valves is
IC CAdjust cable out until freeplay is removed from cable, but an audible click can still be heard when repeating Step and
BDTurn the adjuster out 14 turn from the point found in Step (raise the exhaust valve) and tighten the lock nut securely
Exhaust Valve Operation To check the operation of the valves: 1Disconnect the mUlti-pin connector at the exhaust valve actuator
box2Using 12 volt shop battery, probe the terminals as listed in the chart below to open and close the valvesDo not leave
battery connected to the exhaust valve actuator wire terminalsContact the terminals momentarily to move the valves in the
desired direction, and then disconnect the probes3Verify the exhaust valves open and close completely4Re-connect the multi-pin