1999 Polaris SLH, SLTH, SLX, SLTX, PRO785 Factory Service Manual, Page 254Get this manual

1999 Polaris SLH, SLTH, SLX, SLTX, PRO785 Factory Service Manual, Page 254

FJNAL DRIVEJET PUMPBILG SYSTEM Pump Alignment Inspection Pump Alignment Inspection, Cont Stud must be fully engaged in hex
hull or pump damage has occurredUse the following procedure to install the pump housingThe pump mounting surface must be
clean and flat before installing pump housing3Place stud in pump housing (long end first) and install flat washer, lock washer
(where applicable) and nutTighten nut while aligning hex portion of stud with recess in housingTighten until hex of stud
is flush with pump housing mounting surface or protrudes slightlyno more than .040" (1 mm)Do not tighten completely at this