1999 Polaris SLH, SLTH, SLX, SLTX, PRO785 Factory Service Manual, Page 305Get this manual

1999 Polaris SLH, SLTH, SLX, SLTX, PRO785 Factory Service Manual, Page 305

ELECTRICAL Battery Maintenance Refilling Low Battery The normal chargedischarge cycle of battery causes the cells to give
knife, remove any corrosion from cables and terminalsMake sure electrolyte is at proper levelAdd distilled water if necessaryCharge
at rate no greater than 110 of the battery's amplhr capacity until the electrolyte's specific gravity reaches 1.270 or greaterStore
battery either in machine with cables disconnected, or store in cool dry placeNOTE: Stored batteries lose their charge at
the rate of per dayThey should be recharged to full charge every 60 to 90 days during non-use periodIf stored during the
winter months, the electrolyte will freeze at higher temperature as the battery dischargesThe chart below indicates freezing
points by specific gravityELECTROLYTE FREEZING POINTS Specific Gravity of Electrolyte 1.265 1.225 1.200 1.150 1.100 1.050
Freezing Point -75F -35F -17F +18F +2JOF Charging Procedure Charge the battery with charger no larger than 110 of the battery's