http:ReadManm MAINTENANCElTUNE UP Electrical Replenishing Battery Fluid The fluid level should be kept between the upper
personal injuryWhen re-installing battery connect black (negative) cable last WARNING Keep the battery away from sparks and
open flames during charging because the battery gives off gases which are explosiveIf you smell fuel do not attempt to charge
the batteryWhen using battery charger connect the battery to the charger before turning on the chargerThis prevents the possibility
of sparks at the terminals which could ignite the battery gasesDo not connect charger cables to the battery unless the charger
is unplugged12Remove caps from cellsAdd distilled water if necessary to bring electrolyte up to proper levelConnect battery
to chargerSet charging rate at 1.9 amps (maximum) and charge battery for ten hours During charging, if the electrolyte temperature
rises above 115F (45C) or if battery feels hot when touched, reduce the charging rate to lower the temperature and increase