2000 Polaris Virage TX, SLX, Pro 1200, Genesis, Genesis FFI Personal Watercraft Service Manual, Page 109Get this manual

2000 Polaris Virage TX, SLX, Pro 1200, Genesis, Genesis FFI Personal Watercraft Service Manual, Page 109

http:ReadManm FUEL SYSTEMCARBURETION Testing Fuel Line Air Leak Testing Fuel lines may develop air leaks causing the PWC
this pressure for five minutesIf pressure will not hold, check hose clamps and fuel shut off valvebe repaired or replacedThis
test should be done on both main fuel line and reserve line, switching the,shut off valve accordingly 2To verify if the shut
off valve is leaking, bypass the valveIf it maintains pressure, the valve is faulty and should 3To check for air leaks from
the fuel pump through the carb rack, remove the fuel line from the fuel pump out line, and remove the return line from the
fuel tank 4Attach one end of the line and install the Mity VacTM on the other endApply to PSI to the lineIt should maintain
that pressure for five minutesIf not, check hose clamps and inspect lines for damageIf after checking lines and clamps no
leaks are found, carbs should be taken apart and inspected Oil Check Valve Testing 1Apply pressure to end of check valve