2000 Polaris Virage TX, SLX, Pro 1200, Genesis, Genesis FFI Personal Watercraft Service Manual, Page 152Get this manual

2000 Polaris Virage TX, SLX, Pro 1200, Genesis, Genesis FFI Personal Watercraft Service Manual, Page 152

http:ReadManm ENGINE Oil Pump Oil Pump Bleeding The oil pump must be bled following any repair service to the injection system
are present, fill oil supply lines with oil using small oil squirt can Troubleshooting NOTE: See Maintenance section for
adjustmentinspection information 75 Remove lines from their fittings at the engine and pumpBlow through them to ensure they
are not plugged or restricted76 Apply some pressure to the check valve fittings with the Mity VacTM or similar toolThese
valves should open with 2-5 Ibsof pressure77 Be sure oil feed lines fit tightly, are not cracked or leaking78 Be sure the
in-line filter between oil pump and oil tank is clean and bleeding is complete79 .If oil still won't flow, replace the oil
pumpNOTE: This machine is equipped with variable oil pump controlled by link rod between the carburetors and the pump armThis